Search
Category
Related Industries
Weekly Insights
Stay ahead with our curated technology reports delivered every Monday.
A solvent meets EU REACH requirements only when its substance identity, supply route and intended use match the obligations that apply to that specific transaction. A supplier’s declaration or a registration number alone cannot establish this. The assessment needs to connect the material received to the relevant registration, restrictions, authorisation status and safety information.
Start with the exact solvent composition and the legal role of each company in the chain. Then compare the intended process and operating conditions with the documents supplied. Keep the evidence with the purchase and material records so that a change in supplier, formulation or use triggers a fresh assessment.
Use the substance name, EC number and CAS number in the safety data sheet (SDS) and technical specification to establish what is being supplied. A trade name such as “cleaning thinner” is not a reliable identifier: it could refer to a single substance, a blend or a composition that varies within a specified range.
For a single-substance solvent, compare its identity and composition with the relevant regulatory entry. Impurities and stabilisers matter when they affect classification or fall within a restriction. A high-purity grade and a recovered grade may share a principal chemical name while having different impurity profiles, so request a specification or certificate of analysis that addresses the relevant constituents.
For a mixture, identify each constituent that is relevant to registration, restriction, authorisation and classification. The mixture itself does not receive a REACH registration number: registration concerns substances. The SDS may disclose only constituents required under the applicable disclosure rules, so an undisclosed ingredient cannot automatically be treated as absent. If a restriction applies to a particular substance at a specified concentration, request a targeted confirmation or compositional evidence from the supplier.
Record the exact question behind any declaration. “Does the product contain substance X above the limit applicable to this use?” is more useful than a broad statement that the solvent is “REACH compliant.” Include the product name, grade, intended use and relevant concentration threshold in the request.
Registration obligations generally apply to substances manufactured in or imported into the EU in quantities of one tonne or more per year per manufacturer or importer, unless an exemption applies. The relevant quantity is the amount of each substance, including substances in mixtures; it is not simply the number of containers or the total mass of a blended product.
The supply route changes the analysis. An EU-based company buying a solvent from an EU supplier is generally a downstream user or distributor for that transaction. A company bringing the same material directly into the EU from a non-EU supplier is generally an importer, unless the non-EU manufacturer or formulator has appointed an only representative covering that import. Incoterms, shipping paperwork and ownership arrangements should be reviewed alongside the actual import arrangement; a sales invoice by itself may not settle the REACH role.
Where an only representative is involved, obtain evidence that the appointment covers the specific non-EU supplier, substance and imported quantity. Confirm how the imported volumes are tracked and whether the relevant imports are included in the representative’s records. A reference to an only representative somewhere in a supplier’s corporate group does not establish coverage for every shipment.
Exemptions also require a documented basis. For example, some recovered substances can benefit from an exemption when the applicable recovery conditions are met, including sameness with a registered substance and availability of required safety information. “Recycled” or “recovered” on a product description is not sufficient evidence by itself.
A registration number in an SDS is useful evidence, but it does not prove that every supplier or use is covered. Confirm that the substance identity matches the material and that the registration relates to the relevant supply chain. Some SDSs omit part of the registration number under permitted conditions, so a shortened number is not automatically a defect. Ask for clarification when the document does not establish the link between the material, registrant and supply route.
Public information from the European Chemicals Agency (ECHA) can help verify substance identity and published registration information. A substance appearing in ECHA’s database does not establish that a particular importer has registered its own imports, that an only representative covers them, or that the intended use complies with restrictions. Likewise, absence of a registration number in an SDS needs investigation rather than an immediate assumption: registration may not apply to that supplier or substance, and SDS disclosure rules vary with the circumstances.
Request current, transaction-specific evidence where the company’s role creates a registration obligation. Keep the supplier’s response, substance identifiers, annual quantity calculation and any applicable exemption rationale together. Reassess when imports increase, the source changes or a mixture’s composition is revised.
REACH restrictions are listed in Annex XVII. Search the current entry using the substance identity and read the complete conditions, including concentration limits, permitted uses, dates and any derogations. A restriction may apply to a substance on its own, in a mixture or in an article; the trigger and obligations are set by the individual entry.
For example, a solvent used in an industrial cleaning bath and the same solvent supplied in a consumer cleaning mixture can fall under different conditions in a restriction. A limit expressed as a concentration in a mixture must be evaluated against the formulation being placed on the market or used, as specified by the entry. The purity of the solvent component alone is not the same measurement as its concentration in the final blend.
Where compliance relies on a concentration limit, establish whether the supplier’s declaration covers the full specification range. A certificate for one batch can support acceptance of that batch, but it does not establish that every future batch will meet the limit. Retain the analytical method, reporting limit and result when testing is used to support the decision.
A substance of very high concern can appear on the Candidate List before it is added to the REACH Authorisation List, Annex XIV. Candidate List status alone does not impose an automatic ban or mean that an authorisation is already required for every use. It can, however, trigger specific communication duties, and it signals that the substance’s regulatory status needs monitoring.
If a solvent constituent is listed in Annex XIV, review the entry’s sunset date, any relevant exemptions and the precise use. After the sunset date, placing it on the market for a use or using it generally requires an authorisation covering that use, unless an exemption or another applicable provision allows the activity. An application or authorisation for one use should not be assumed to cover a different process.
When relying on an authorisation granted to an actor higher in the supply chain, obtain the authorisation details and verify that the use and conditions cover the site’s activity. Downstream users relying on such an authorisation also have notification obligations to ECHA. Compare the authorised conditions with the actual equipment, exposure controls and operating practices before accepting the solvent for that use.
An SDS is a primary operating document, but its value depends on whether it corresponds to the supplied product and current use. Verify the product identifier, supplier details and revision date, then review the composition, hazard classification, handling and storage requirements, exposure controls and disposal information. Where an SDS is required, it must follow the applicable REACH requirements and be supplied in the official language or languages required by the Member State where the substance or mixture is placed on the market.
For a hazardous substance registered at ten tonnes or more per year, the registrant’s chemical safety assessment generally includes exposure scenarios for relevant identified uses. When applicable, these scenarios are annexed to the SDS. Mixture suppliers can communicate relevant safe-use information through an SDS for the mixture, including in its main body or an annex; the absence of a separate exposure-scenario annex for the mixture does not by itself prove non-compliance.
Compare the described use with the process rather than relying on a generic phrase such as “industrial use.” Relevant differences include open versus enclosed handling, transfer method, duration, temperature, ventilation, emission controls and the concentration of the substance in the mixture. A scenario covering closed transfer at ambient temperature cannot automatically be applied to manual pouring into a heated vessel.
If the use or conditions are outside the information received, clarify the situation before relying on the document. Options under REACH can include communicating the use to the supplier, adapting the process to the communicated conditions, identifying a suitable supply route or preparing a downstream-user chemical safety report where required. Applicable exemptions and reporting duties must be assessed for the particular situation.
Conflicting documents often reveal the most useful questions. If the SDS names one substance while the certificate of analysis uses a broader solvent family, establish whether they describe the same composition. If the restriction declaration refers to a different grade, obtain a corrected declaration. If the purchase specification permits a concentration range that crosses a regulatory threshold, tighten the specification or require evidence for each affected batch.
Place the material on hold when a required condition cannot be substantiated. The hold record should identify the unresolved issue, the affected grade and use, the evidence requested and the person responsible for its resolution. A revised SDS may resolve a documentation mismatch; a restricted use or missing registration coverage may require a change to the material or supply arrangement.
Maintain the assessment against the current legal text and ECHA information, with a review date and links or copies of the sources used. Reopen it when the composition, intended use, supplier or legal status changes. That record makes the basis for accepting the solvent traceable at the point of receipt and during later reviews.