Search
Category
Related Industries
Weekly Insights
Stay ahead with our curated technology reports delivered every Monday.
There is no single REACH certificate that proves a chemical product is compliant. The documents required under EU REACH depend on whether a company manufactures, imports, distributes or uses a substance; whether the product is a substance, mixture or article; and whether registration, safety data sheet, authorisation or restriction obligations apply.
REACH compliant chemical documentation may include registration records, safety data sheets, exposure scenarios and evidence supporting safe use. The critical distinction is between documents that must be submitted to the European Chemicals Agency (ECHA), information that must travel with a product, and records a company must retain or make available to authorities.
REACH, Regulation (EC) No 1907/2006, generally places registration duties on EU/EEA manufacturers and importers of substances at one tonne or more per year per legal entity, unless an exemption applies. Registration concerns substances on their own, in mixtures and, in certain circumstances, in articles—not mixtures as finished products. An EU/EEA-based only representative can take over the relevant importer obligations for imports covered by its appointment by a non-EU manufacturer, formulator or article producer.
That distinction changes the evidence needed. A non-EU supplier’s statement that a substance is “REACH registered” does not by itself show that a particular EU importer’s volume is covered. The importer needs to establish who holds the registration, whether the substance and supply are covered, and whether any only representative arrangement applies to its imports.
The documentation assessment should therefore connect each material to its substance identity, supplier, legal entity, annual volume and intended uses. For a mixture, this means considering the component substances rather than looking only at the trade name. A valid safety data sheet for the mixture does not replace any registration duties that apply to its individual ingredients.
Where registration is required, the registrant submits a dossier to ECHA. Its technical dossier contains information such as substance identity, manufacture and uses, classification and labelling, guidance on safe use, and relevant study information. Information requirements depend on the tonnage band and the applicable REACH annexes; registrants may also use permitted adaptations where justified.
For registrations at 10 tonnes or more per year, a chemical safety report (CSR) is generally required, subject to applicable exceptions. It documents the chemical safety assessment. Where the substance meets specified hazard criteria or is assessed as persistent, bioaccumulative and toxic, or very persistent and very bioaccumulative, the assessment includes exposure assessment and risk characterisation for identified uses.
A registration number confirms that ECHA has assigned a number to a submission; it is not a certificate that ECHA has approved every use or verified that the dossier is complete and correct in all respects. It also does not prove that a different legal entity’s imports are covered. Supporting records should allow the company to trace the registered substance, registrant, relevant tonnage band and supply arrangement. Where an only representative is involved, the parties should retain evidence of the appointment and the imported quantities covered.
A distributor or downstream user does not normally need a copy of the supplier’s confidential registration dossier. What matters is obtaining the information it needs for its own obligations, including the registration number in the safety data sheet where required, relevant safe-use information and clarification of any coverage issue affecting the supply.
An EU REACH safety data sheet (SDS) is required in several circumstances, including when a substance or mixture meets the criteria for classification as hazardous under the CLP Regulation. An SDS is also required for a substance that is persistent, bioaccumulative and toxic, or very persistent and very bioaccumulative, under REACH Annex XIII, or is included on the Candidate List for reasons other than those classifications.
Certain mixtures that are not classified as hazardous must also be accompanied by an SDS on request when they contain specified hazardous or concerning substances above the applicable thresholds. The absence of a hazard classification for the finished mixture is therefore not enough to conclude that no SDS obligation exists.
The supplier must provide the SDS free of charge, on paper or electronically, no later than the first supply. It must be in an official language of the Member State where the substance or mixture is placed on the market, unless that Member State provides otherwise. The SDS follows the 16-section format and content requirements of REACH Annex II, as amended, including those introduced by Regulation (EU) 2020/878.
Checking only that an SDS has 16 headings is insufficient. The document should be consistent across substance identity, composition, classification, exposure controls, storage, transport and disposal information. For example, a change in solvent composition can affect both the hazard classification and the protective measures described in the sheet. The SDS should also correspond to the product actually supplied, not merely to a similarly named grade.
Suppliers must update the SDS without delay when relevant new information on hazards or risk management becomes available, when an authorisation is granted or refused, or when a restriction is imposed. The revised version must be supplied to recipients who received the substance or mixture within the preceding 12 months. A document-control system should preserve the revision date and link each version to the affected product and recipient records.
Where a registrant must prepare a CSR and exposure assessment is required, relevant exposure scenarios are annexed to the SDS supplied for the substance. These extended SDSs describe conditions under which identified uses are considered controlled, including operational conditions and risk management measures.
The practical question is not simply whether an exposure scenario is attached. The receiving company must check whether its use and conditions are covered. A scenario for industrial use in a closed system, for example, cannot automatically be treated as covering an open manual transfer operation. Duration, concentration, ventilation, containment, personal protective equipment and environmental controls can all affect the comparison.
If a use or its conditions fall outside the supplier’s exposure scenario, the downstream user has several possible routes under REACH, depending on the circumstances. These can include asking the supplier to make the use an identified use, adapting its operating conditions, changing supplier or substance, or preparing a downstream user chemical safety report where required. Exemptions from the downstream user report requirement exist; relying on one requires checking its conditions. In certain cases, the downstream user must also report information to ECHA.
Records of the comparison between the exposure scenario and site conditions are valuable evidence of how the company reached its conclusion. They can link the relevant scenario to operating instructions, ventilation controls, protective equipment and environmental measures. Such records should be reviewed when the process or supplier’s safe-use advice changes.
For mixtures, safe-use information may be communicated in different ways, including through information integrated into the mixture SDS or supplied separately. A mixture does not necessarily arrive with a single exposure scenario covering every component and use. The key is whether the information received enables the recipient to identify and apply the necessary controls.
The absence of an SDS requirement does not mean that no REACH information must be communicated. Article 32 requires suppliers of substances on their own or in mixtures to provide relevant information in specified circumstances where an SDS is not required. This includes, where applicable, registration numbers, information on authorisations and restrictions, and other available and relevant information needed to identify and apply risk management measures.
This information must be supplied free of charge no later than the first delivery and updated when specified new information becomes available. A short supplier declaration may be useful if it addresses the actual regulatory conditions, but a generic statement that a product is “REACH compliant” does not explain whether a restriction applies or what controls are necessary.
Registration is only one part of REACH. A registered substance can still be subject to an Annex XVII restriction that limits its manufacture, placing on the market or use. The relevant document is the evidence needed to demonstrate that the specific restriction’s conditions are met. Depending on the entry, that may involve composition data, concentration calculations, test reports, use specifications or supplier information. A general declaration should identify the applicable restriction and the basis for the claim.
Substances listed in Annex XIV may not be placed on the market for a use, or used, after the applicable sunset date unless an authorisation applies or the use is exempt. Where an authorisation covers the activity, the company should retain the relevant decision and verify that the substance, use, supply chain and conditions match. An authorisation number on a label is useful information, but it does not replace a review of the decision’s conditions. A downstream user relying on an authorisation granted to an actor up its supply chain must notify ECHA within three months of its first supply of the substance.
Articles require a different assessment from substances and mixtures. Under Article 33, a supplier of an article containing a Candidate List substance above 0.1% weight by weight must provide the recipient with sufficient available information to allow safe use, including at least the substance name. Consumers can request this information and must receive it free of charge within 45 days. The concentration assessment applies to the individual article, including an article incorporated into a complex object.
Article producers or importers may also need to notify ECHA under Article 7(2) when a Candidate List substance is present above 0.1% weight by weight and totals more than one tonne per producer or importer per year across the relevant articles, unless an exemption applies. Separately, an article substance intended to be released under normal or reasonably foreseeable conditions of use may require registration when the applicable one-tonne threshold is met and no exemption applies.
REACH Article 36 requires manufacturers, importers, downstream users and distributors to assemble and keep available the information they require to carry out their duties for at least 10 years after they last manufactured, imported, supplied or used the substance or mixture. This is distinct from simply retaining the latest SDS: older versions, use assessments and supply records may explain what information was available when a particular batch was handled.
A workable record links the legal entity and supplier to the substance or mixture, product identity, relevant volumes, applicable SDS version, exposure scenario assessment and any restriction or authorisation evidence. Where a decision rests on a supplier statement, the record should show what was declared, which product and substances it covers, and when it was issued.
Documentation should be revisited when a supplier changes, an ingredient or grade changes, an SDS is revised, a new use is introduced or a relevant restriction or authorisation condition changes. The objective is not to accumulate every possible document, but to maintain a traceable basis for the obligations that actually apply.
Primary references: Regulation (EC) No 1907/2006 (REACH); Regulation (EU) 2020/878 amending REACH Annex II; and ECHA’s REACH guidance and regulatory information. Consult the consolidated legislation and current ECHA information when assessing a particular substance or use.
Recommended News